Shanghai Fengqi Industry Development co.,ltd.

Your location:Home > Products > Valves > Control Valves >

Valves

Self-reliance Pressure Regulator

Self-reliance Pressure Regulator
Self-reliance Pressure Regulator

Features

Self-reliance type pressure regulator attached temperature tank can be continuous under 350℃ steam. Shanghai Yihuan flow control equipment Co.,ltd produced self-reliance type pressure regulator is widely used in urban heating, heating system, petroleum, chemical industry, electric power, metallurgy, food, light industrial equipment gases, liquids, steam and other media pressure relief valves, constant pressure.
Self-reliance type pressure regulator without needing external energy, using medium itself power as power supply, leading in actuator control core position, change two ends pressure differential and flow, makes the pressure stable before valve (or after). It has the smart action, good sealing performance, pressure setting point small fluctuations advantages, is widely used in gas, liquid and steam medium depressure stabilizing pressure or automatic control. This series of products are single seat (ZZYP), sleeve (ZZYM), double seat(ZZYN) three structures: actuators have diaphragm, piston type two kinds: acting types decompression after valve pressure regulating (B type) and pressure regulating before pressure relief valve (K type). Nominal pressure rating has PN16, 40, 64, Valve size range DN20 ~ 300, Leakage class is class II, level IV and VI, Flow characteristic is fast opening, Pressure section adjustment is 15 ~ 250Mpa. Can combine according to need in order to meet user requirements.

Technical parameters and performance indicators

body:ZG230-450、ZG1Cr18Ni9Ti 、ZGCr18Ni12MoTi
core:1Cr18Ni9Ti、Cr18Ni12Mo2Ti
seat:1Cr18Ni9Ti、Cr18Ni12Mo2Ti
stem:1Cr18Ni9Ti、Cr18Ni12Mo2Ti
diaphragm cover:A3、1Cr18Ni9Ti packing:PTFE, flexible graphite
diaphragm: NBR, oil resistant rubber, fluororubber

Detail technical parameters

DN(mm) 20 25 32 40 50 65 80 100 125 150 200 250 300
rated flow coefficient Kv 7 11 20 30 48 75 120 190 300 480 760 1100 1750
rated stroke L(mm) 8 10 14 20 25 40 50 60 70
PN(Mpa) 1.6、4.0
pressure adjustable scope(Kpa) 15~50、40~80、60~100、80~140、120~180、160~220、200~260
240~300、280~350、330~400、380~450、430~500、480~560、540~620、
600~700、680~800、780~900、880~1000、600~1500、1000~2500
intrinsic flow characteristic fast open
adjustable accuracy(%) ±5
applicable temperature(℃) ≤350
allowed leakage hard sealing (1/h) signle seat:≤10-4×rated volume(Ⅳ), double seat and sleeve:≤5×10-3 rated volume(Ⅱ)
soft sealing (m1/min) 0.15 0.30 0.45 0.60 0.90 1.70 4.0 6.75 11.10 16.0
decompression Max. 10
Min. 1.25

External dimensions (unit:mm)Note: the flange length according to PN16

Self-reliance Pressure Regulator Structure
Self-reliance Pressure Regulator Structure
Self-reliance Pressure Regulator Dimensions Diagram
Self-reliance Pressure Regulator Dimensions Diagram
(DN) 20 25 32 40 50 65 80 100 125 150 200 250 300
flange length (L) 185 200 205 222 254 276 298 352 410 451 600 670 735
total height (H) 615 645 650 710 730 745 760 800 890 960 1050    
H1 52.5 57.5 67.5 72.5 80 90 97.5 107.5 122.5 140 167.5 225 230
D 100
H 280
flange standard GB:PN1.6、2.5、4.0Mpa   ANSI:150、300Lb    JIS:10K、20K

Installation diagram

Self-reliance Pressure Regulator Installation Diagram A
Self-reliance Pressure Regulator Installation Diagram B

Measuring gas, pressure regulating before valves (K type), can not install filter Measuring gas, pressure regulating after valves (K type), can not install filter

Self-reliance Pressure Regulator Installation Diagram C

Measuring liquid, pressure regulating before valves (K type), should install filters for the uncleaning fluid

Self-reliance Pressure Regulator Installation Diagram D

Measuring liquid, pressure regulating after valves (B type), should install filters for the uncleaning fluid

Self-reliance Pressure Regulator Installation Diagram E

Measuring steam, pressure regulating before valves (K type), should install insulation tank, suggest install filters

Self-reliance Pressure Regulator Installation Diagram F

Measuring steam, pressure regulating after valves (B type), should install insulation tank, suggest install filters